Ticket #221 ( Closed )

Short Description Same problem as #193 but I am using 5250 emulation
Entered By: pdo When: 1998-12-03 17:27:03 Build: 1.04.1Beta
Categories Type: Question   Department: Product   Category: Evaluation
Description
I am trying to demo your product (V1.04) to see if we can use the 5250 emulator. If I do a start on the session inside of console the session pops up with only an input feild for the password, nothing for the userid. If I start the session through normal panels I see no fields to enter data into. I would love to turn on the log function for you, but uner my settings there does not appear to be one. Any help would be greatly appreciated. PS - 3270 seems to work great!
Append By: WindSurfer  When: 1998-12-04 09:25:37  New Status: Pending Customer
Comment Sorry for the delay in responding--

To log, use the Screensurfer Service Control Applet and start in "Diagnostic Mode". Connect to your 5250 Signon Screen...then stop the service.

This produces a file \Screensurfer\hostserver\surfdiag.log - please e-mail this file as an attachment to surfer@ieinc.com, with "Ticket193" in the subject.

I believe we have a fix already for this issue, as there is a field attribute issue in some sign-on screens that our screen-to-HTML converter trips-up on. If we can get your log file we can verify that we have the fix and get it to you later today.

Thank you for using the SupportCenter!

Append By: pdo  When: 1998-12-04 12:14:51  New Status: Pending IE
Comment You should have the E-Mail with the log by now. (I sent it off earlier this morning. If not let me know.
Append By: WindSurfer  When: 1998-12-07 15:46:52  New Status: Pending Customer
Comment PDO, new build is available at: ftp://ftp.ieinc2.com/pub/surfer/t1_4_2a.zip

Unzip to \screensurfer\bin to replace ielua.exe.

Problem was with an attribute byte being incorrectly translated...

Append By: pdo  When: 1998-12-08 13:58:31  New Status: Pending IE
Comment Installed new ielua. From gateway screen I only see the userid field - no password field. If I go into administrator console, and do a details on the session, I see and can enter into both fields. What have I got wrong?
Append By: WindSurfer  When: 1998-12-08 14:21:35  New Status: Pending Customer
Comment Hmmm, will check what went wrong-- this is reproducing today, even though a "straight" as400 is working great...will fix immediately. Expect something in the next 30 minutes!